About FEP HOOK UP WIRE
PTFE Cable Specification
| Conductor : |
Silver or Nickel or Tinned Plated Copper or Bare Copper Wire. |
| Insulation : |
PTFE Wrap or PTFE / Polyamide / PTFE Combination or PTFE / FG |
| Properties : |
Resistance to Fire, Chemicals, Acids, Sunlight and Moisture. |
| Voltage Grade : |
250 V, 600 V or 1000 V and above as per customer requirement. |
| Temperature : |
-65 C to + 260 C |
| Size : |
AWG 32 to AWG 1 and ( AWG 0 to AWG 0000 on request only ) |
| AWG |
Number Of standard |
AWG |
Nominal Conductor Diameter(MM) |
Nominal Stand Diameter |
Nominal Cross Sectional Area (sq.MM) |
Maximum Resistance Ohms/100m At 20C |
ET(250V AC RMS) Nom. O.D.(MM) |
E(600V AC RMS) Nom. O.D.(MM) |
EE(1000V AC RMS) Nom. O.D.(MM) |
| 8 |
133 |
29 |
4.290 |
0.286 |
8.54 |
0.217 |
- |
- |
5.30 |
| 10 |
37 |
26 |
2.835 |
0.405 |
4.76 |
0.390 |
- |
- |
3.586 |
| 11 |
37 |
27 |
2.520 |
0.360 |
3.76 |
0.499 |
- |
3.02 |
3.27 |
| 19 |
24 |
2.550 |
0.510 |
3.88 |
0.489 |
- |
3.05 |
3.30 |
| 12 |
37 |
28 |
2.240 |
0.320 |
2.98 |
0.620 |
- |
2.74 |
3.99 |
| 19 |
25 |
2.275 |
0.455 |
3.09 |
0.600 |
- |
2.775 |
3.02 |
| 13 |
19 |
26 |
2.000 |
0.405 |
2.45 |
0.770 |
- |
2.50 |
2.75 |
| 14 |
37 |
30 |
1.750 |
0.250 |
1.92 |
0.98 |
- |
2.25 |
2.50 |
| 19 |
27 |
1.800 |
0.360 |
1.93 |
0.96 |
- |
2.30 |
2.55 |
| 15 |
19 |
28 |
1.600 |
0.320 |
1.52 |
1.22 |
- |
2.10 |
2.35 |
| 16 |
37 |
32 |
1.400 |
0.200 |
1.16 |
1.54 |
- |
1.90 |
2.15 |
| 19 |
29 |
1.430 |
0.286 |
1.22 |
1.51 |
- |
1.93 |
2.18 |
| 18 |
37 |
34 |
1.120 |
0.160 |
0.74 |
2.50 |
- |
1.93 |
2.18 |
| 19 |
30 |
1.250 |
0.250 |
0.93 |
1.93 |
- |
1.75 |
2.00 |
| 7 |
26 |
1.215 |
0.405 |
0.90 |
2.10 |
- |
1.715 |
1.96 |
| 20 |
37 |
36 |
0.910 |
0.130 |
0.49 |
3.44 |
1.21 |
1.41 |
1.66 |
| 19 |
32 |
1.000 |
1.000 |
0.60 |
3.02 |
1.30 |
1.50 |
1.75 |
| 7 |
28 |
0.960 |
0.320 |
0.56 |
3.28 |
1.26 |
1.46 |
1.71 |
| 22 |
19 |
34 |
0.800 |
0.160 |
0.38 |
4.90 |
1.10 |
1.30 |
1.55 |
| 7 |
30 |
0.750 |
0.250 |
0.34 |
5.20 |
1.05 |
1.25 |
1.50 |
| 1 |
22 |
0.645 |
0.645 |
0.33 |
5.60 |
0.94 |
1.14 |
1.39 |
| 24 |
19 |
36 |
0.650 |
0.130 |
0.25 |
7.70 |
0.95 |
1.15 |
1.40 |
| 1 |
24 |
0.510 |
0.510 |
0.20 |
8.80 |
0.81 |
1.01 |
1.36 |
| 7 |
32 |
0.600 |
0.200 |
0.22 |
8.20 |
0.90 |
1.10 |
1.35 |
| 26 |
19 |
38 |
0.500 |
0.100 |
0.15 |
12.00 |
0.80 |
1.00 |
1.25 |
| 7 |
34 |
0.480 |
0.160 |
0.14 |
13.20 |
0.78 |
0.98 |
1.23 |
| 1 |
26 |
0.450 |
0.405 |
0.13 |
14.10 |
0.70 |
0.90 |
1.15 |
| 28 |
7 |
36 |
0.390 |
0.130 |
0.90 |
20.93 |
0.69 |
0.89 |
1.14 |
| 1 |
28 |
0.320 |
0.320 |
0.80 |
22.50 |
0.62 |
0.82 |
1.07 |
| 30 |
7 |
38 |
0.300 |
0.100 |
0.05 |
32.50 |
0.60 |
0.80 |
1.15 |
| 1 |
30 |
0.250 |
0.250 |
0.05 |
35.70 |
0.55 |
0.75 |
1.00 |
| 32 |
7 |
40 |
0.240 |
0.080 |
0.04 |
54.60 |
0.54 |
0.74 |
0.99 |
| 1 |
32 |
0.200 |
0.200 |
0.03 |
55.90 |
0.50 |
0.70 |
0.95 |
Superior Flame Retardance and SafetyFEP Hook Up Wire provides excellent flame retardance, meeting rigorous UL safety ratings for secure use in demanding environments. The insulation resists ignition and the wire maintains integrity under voltage surges, helping protect sensitive electronic circuits in appliances and medical devices alike.
Exceptional Chemical and Moisture ResistanceThanks to its FEP insulation, this hook up wire delivers outstanding resistance to chemicals and moisture. This makes it highly reliable for internal wiring applications where environmental exposure or corrosive substances could compromise lesser materials. Its sleek, glossy surface finish further supports durability.
Flexible Design for Tight SpacesThe wires flexibility ensures easy routing through compact or densely packed wiring spaces. Available in different sizes (18 AWG to 30 AWG), both stranded and solid conductor types assist varied installation requirements in electronics, equipment, and precision devices.
FAQs of FEP HOOK UP WIRE:
Q: How does FEP Hook Up Wire perform in high-temperature environments?
A: FEP Hook Up Wire operates effectively in temperatures ranging from -65C to +200C, making it well-suited for both low- and high-temperature conditions encountered in industrial, medical, and electronic equipment.
Q: What are the benefits of its excellent chemical resistance?
A: Its outstanding resistance to chemicals ensures long-lasting performance in environments exposed to oils, solvents, and corrosive substances, reducing risk of insulation degradation and electrical failure.
Q: When should you use FEP Hook Up Wire for electronic equipment?
A: FEP Hook Up Wire should be used for internal wiring applications requiring high electrical insulation, moisture resistance, flexibility in tight spaces, and flame retardancesuch as in precision electronic devices and medical equipment.
Q: Where is FEP Hook Up Wire commonly applied?
A: This wire is suitable for use in electronic equipment, appliances, medical devices, and other electrical machinery where reliable internal wiring is critical.
Q: What is the process for selecting the appropriate FEP Hook Up Wire?
A: Selection depends on application requirements, including wire gauge (size), insulation thickness, rated voltage, color, and conductor type (solid or stranded). Customers can specify custom lengths and connector types to fit their needs.
Q: How does the wire support high-frequency performance?
A: With FEP insulation and tinned copper conductors, the wire maintains excellent performance from DC to several GHz, ensuring signal integrity in demanding, high-frequency electronic circuits.